HMD-500 - American Sensors Corp.

HMD-500

SCANNING HOT METAL DETECTOR

NON-CONTACT, RELIABLE, PRECISE, LONG-RANGE PRODUCT DETECTION FOR ALL PRODUCTS FROM 150°C (300°F) EVEN IN THE PRESENCE OF STEAM, SCALE AND WATER

FEATURES:

  • Visible Aiming Laser
  • Detects at a distance of 0.2 Meters to 8 Meters
  • Modern microcontroller-based design with digital conditioning of detect signal
  • Mill-duty Housing with Water-Cooling and Positive-Pressure Air-Purge
  • Normal/High Sensitivity selection remotely and on the back of sensor
  • 24 VDC or 100 - 240 VAC, 50 hz / 60 hz

APPLICATIONS:

The HMD-500 is the best designed, and the most precise detection system for all hot metal applications including:

MADE IN USA
  • Tracking
  • Cut-to-Length
  • Positioning
  • Cooling Beds
  • Width Control
  • Caster Torches
  • Annealing

Description:


Specifications:

VERTICAL ANGLE DETECTION +/- 5°; +/- 15°; +/- 22°
HORIZONTAL ANGLE DETECTION Adjustable max. 3
LASER POSITIONING 650nm (Red), Class 2
DETECT DISTANCE 0.2m – 8m
DETECTION THRESHOLD Adjustable via potentiometer at back of sensor
ENERGY Signal amplitude 0-13.5V and displayed at back of sensor
SWITCHING POWER 350VA with 250V Max.
10A Max
RELAY CLOSING TIME 7.5 ms
RELAY OPENING TIME 3ms
RELAY OUTPUT SPDT Relay 5 Amp at 250 VAC
SOLID STATE OUTPUT TTL Transistor Output
24V Push/Pull
RESPONSE TIME
(TRANSISTOR OUTPUT)
1 ms (5°) 2 ms (15°); 4ms (22°)
GAIN LEVELS High & Low
THRESHOLD SETTINGS TH / TL
ENERGY OUTPUT 0-10V
TEST FUNCTION Built-in self-test and diagnostics
POWER SUPPLY Universal Input 100 to 240VAC, 50-60 Hz.
Or 24VDC
POWER CONSUMPTION 20VA or 10VA (for 24V)
HOUSING Cast aluminium housing rating IP66 (NEMA4)
WATER/AIR COOLING Water / Air-cooling Jacket
PROTECTIVE HOOD Hinged protective hood with positive pressure air purge: 4-16 liters/min. (0.14 to 0.56 ft3/min ) at 2 bars (29 PSI)
MOUNTING Fully adjustable foot mount swivel stand
CABLE 2 meter, Standard, high-temperature Teflon shielded
CONNECTOR Standard: Quick-disconnect Harting plug
SERIAL LINK DIGITAL COMMUNICATION n.a.
OPERATING TEMPERATURE -10°C to 60°C (14°F to 140°F)
Above 60°C (140°F), auxiliary cooling is required: 1-2 bars at 1-2
liters/min (14.5 to 29 PSI at 0.035 to0.07 ft3/min)
INSIDE TEMPERATURE Alarm (fail safe)
STORAGE TEMPERATURE -20°C to 70°C (-4°F to 158°F)
TOTAL WEIGHT 12.25 kg / 27 lbs

Dimensions:

Notes:
  • All models are equipped with adjustable sensitivity switch on back of sensor. The standard model has remote senstivity switch and potentiometer as well as analog signal amplitude output.

    Ordering Information:

    Sensor:
    Vertical Scan AngleInput Voltage
    HMD-510 –   +/- 5°100-240 VAC
    530 –   +/- 15°24V DC
    540 –   +/- 22°

    Cable:
    Part #Standard CableLengthAdditional Length
    HL20015Teflon-shielded with female Harting connector2 meters___ meters

    Our standard cable length is 2 meters (HL20015). ASC can supply any length of cable. When ordering, please specify if additional length is required.





  • Copyright American Sensors Corp. 1993-2014 All Rights Reserved
    557 Long Road, Pittsburgh, PA 15235, U.S.A.
    Tel: 412-242-5903 Fax: 412-242-5908 E-mail: sales@americansensors.com